Get complete information related to latest Lighting Protection Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lighting Protection Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lighting Protection Tenders.
Tender For supply, installation, testing and commissioning (as the case may be) of block proving by axlecounter using block panel and ufsbi for double line operation as per rdso specification no . irs:s-105/2012 (ver.0) with latest amendment. each set consisting of following; (i) universal fail safe block interface complete with all accessories as per sepc. irs:s-104/2012 (ver.0) with attest version and amendment qty-2 nos. (ii) block panel complete with all accessories as per rdso drawing no. rdso/s/32017 for double line (with latest amendment).- qty-02nos. (iii) relay rack with die locking and sealing arrangement as per rsso drg.no. rdso/s/32018 with latest amendment and supplu of all type of relays (iv) block telephone with accessories as per rdso spec. no. rdso/spn/191/2006. qty ? 02 no. with all type lightingprotection. (v) automatic media changeover of modems working on redundant channels for data transmission on ofc/ quad-1 pair and secondary modem for ufsbi for use with secondary media ofc/quad-1 pair. or supply, installation, testing and commissioning (as the case may be ) of microprocessor based station master block panel fordouble line block instrument with block telephones as per rdso/ spn/175/2005 and description: (i) microprocessor based station master block panel for double line instrument with block telephones as per rdso/spn/175/2005- version 1 or latest (b) block telephone as per rdso specification no. rdso/spn/191/2005 or latest ? qty-2 nos. (ii) microprocessor based ssbpac (d) block instrument for double line as per rdso /spn/175/2005 version 1 or latest ? qty 2 nos. (iii) lightening and surge protection devices for power line 24v dc,class-c qty. 2 nos. (iv) lightening and surge protection devices data lines class- d qty. 2 nos. (v) supply ofall type of relays? for double line (vi) auto communication changeover units working on redundant channels for data transmission on ofc/quad-1 pair and secondary modem for use with secondary media ofc/quad-1 pair. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : repair replacement of earth chamber, earth testing point, lightingprotection, measurement of earth test results in zone a to d at mil stn agartala
Tender For upgradation of protection arrangements for signalling systems through modifications in the indoor signalling, underground cable provision, earthing, bonding and lightning protection system in accordance with rdso tan sts/e/tan/3006 ver 3.0 or latest over palakkad division.
Tender For upgradation of protection arrangements for signalling systems through modifications in the indoor signalling, earthing, bonding and lightning protection system in accordance with rdso tan sts/e/tan/3006 ver 3.0 or latest over palakkad division.
Tender For supply of provision of external lightning protection system at rupsi airport d d -sitc air terminal rod of parallel clamp to connect of minimum d 8mm l 500mm air termination rod , sitc of minimum 8mm roof conductor , sitc of roof conductor holder for metal roofs with a stst clamping piece round standing seam roof conductor holder for metal roofs for fixing additional air termination systems , sitc of universal connector for interconnecting roof conductor and down conductor , sitc of clamp for connection to steel or metal constructions , sitc of down conductor holder stst for of minimum rd 8 to 10 mm h 20 mm with female thread m8 preassembled with plastic base complete as required , sitc of glue dispenser of minimum 490gm complete as required , sitc of gi flat of minimum 25 x 6mm for termination to earth pit complete as required , sitc of uni disconnecting clamp with intermediate plate for round and flat conductor , sitc of gi strip holder complete as required , sitc of copper bonded rod with low carbon steel , sitc of lightning strike counter for digital recording of impulse currents , sitc of cui conductor the dangerous area of touch and step voltages for living beings is defined , sitc of conductor holders for installing the cui conductor on walls or facades , sitc of 3 phase or type1 plus 2 kema certified lightning current and surge protection device at mains lt panel , sitc of lightning equipotential bonding isolating spark gap according to 100 ka